01 Evidence path
Digital clamp meter 400V max AC amps is a marking, not a full spec
Read a digital clamp meter 400V max AC amps line as one cell. It does not state true-RMS, crest factor, CAT rating, frequency range, or calibration traceability. LinkScope Sourcing 52 uses this page to show which extra cells to demand before an alternate model is accepted.
- Marking on the jaw
- Datasheet revision
- Safety category
- Certificate date
- Quote exclusions
How to test the marking against the datasheet
Environment to record: the conductor size, the position of the conductor in the jaw, ambient temperature near 23 C if the accuracy table uses that point, and the source frequency. Method: compare the printed 400V and ampere figures with the table row, not with the carton photo. Data to keep: model, revision, accuracy as percent of reading plus counts, and the crest factor at which the table still applies. Steps: photograph the nameplate, attach the datasheet revision, list missing cells, and only then ask a second factory for an alternate.
| Cell | Example question | Why it changes the buy |
|---|---|---|
| 400V max | Is 400V the measurement range, the terminal rating, or marketing text? | A voltage range and a CAT working voltage are different numbers. |
| AC amps | What is the top range, 400 A or another figure, and the resolution? | The search phrase does not fix the ampere range. |
| Frequency range | Does accuracy hold from 40 Hz to 400 Hz, or only at 50 Hz and 60 Hz? | Harmonics from a drive sit outside a narrow band. |
| Safety category | Is the pair CAT III 600 V, CAT III 300 V, or unmarked? | IEC 61010-1 category is requested per model. This page does not certify it. |
| Calibration | Is the certificate dated within 12 months of shipment and tied to the serial? | An undated family claim is not traceability. |
Selection trade-offs before you accept an alternate
True-RMS versus average-responding, on four columns. Bandwidth: true-RMS tables often name a wider frequency range, while average-responding tables may be valid mainly on a sine wave. Crest factor: ask whether error stays inside the stated percent at crest factor 2 and at crest factor 3. Display: both can show the same counts. Price: the average-responding unit can carry a lower unit price and still be the wrong tool on a distorted feeder. Do not subtract the prices until the RMS method matches.
New versus refurbished, same four columns. Warranty start and calibration date favor many new serials. A refurbished unit can be the available match for a legacy jaw the crew already uses, if the seller names replaced parts and the remaining interval. Connector wear on the input jacks is a mating-cycle question for both. Treat them as two offers.
Limits of the 400V phrase: it does not prove the meter may clamp a 400 V bus; it does not set measurement accuracy; it does not include the probe; and a flexible coil sold beside it can have its own scaling error. Ingress protection is a separate code if the meter leaves the bench. Power rating of the battery is irrelevant to the ampere reading but it does decide whether a 40-hour runtime claim is even on the datasheet.
Evidence questions to paste into the RFQ
Which document shows the 400V figure?
Ask for the datasheet page, not a marketplace title. If the title says digital clamp meter 400V max AC amps and the table says something else, the table wins for the brief.
What arrives if the certificate is missing?
Hold the line as incomplete. A later PDF that names a different range does not repair the gap.
Can a compatible probe inherit the meter category?
No, not by default. The probe needs its own voltage and category statement. Impedance and fuse rating stay on that line.
Compare quotes only after the cells match
Send the marking, the range you actually need, the safety category you are asking the supplier to confirm, the quantity, and the destination. The form collects that brief. It does not upload a file.
Request Factory QuotesReview inquiry options if you still need a product name on the form.